Heat.net

Heat.net Store Home


5 TON Tri Zone Ductless Mini Split Air Conditioner Heater, 18000 + 24000 x 2 BTU For Sale


5 TON Tri Zone Ductless Mini Split Air Conditioner Heater, 18000 + 24000 x 2 BTU
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.

Buy Now

5 TON Tri Zone Ductless Mini Split Air Conditioner Heater, 18000 + 24000 x 2 BTU:
$5142.00

5 Ton Tri Zone Mini Ductless Split Air Conditioner 60000 BTU

66,000 BTU Ductless Mini Split AC
16 SEER Efficiency w/ Heat Pump Technology
With a 66000 BTU total Cooling-Heating Capacity, this Inverter DC mini split system can cool or heat 3 seperate 18000-24000-24000 BTU zones [900 ft² + 1200 ft² + 1200 ft²] for a total coverage area of 3300 ft². A 16 SEER rating coupled with Inverter technology provides the benefits of low operation temps, rapid cooling as well as maximum energy efficiency. Includes LCD remotes and complete installation kits with 25\' [x3] of KitSetup - Data:
System Includes:
  • 66000 BTU Cooling Capacity: 18k + 24k + 24k
  • 66000 BTU Heat Pump Capacity:18k + 24k + 24k
  • INVERTER DC TECHNOLOGY: 16 SEER
  • TRI-Zone Setup (3 Air Handlers)
  • 1 Year Warranty on all PartsView Details >
  • 5 Year Warranty on CompressorView Details >

  • Indoor Units - Air Handler [x 3]
  • Outdoor Unit - Compressor rated at 60000 BTU\'s
  • Digital, Multi-function LCD Remote Control [x 3]
  • Installation Kits [x 3] and Product Manual
  • Filtration Screens - Multi Folds Evaporator

Top Line Features:
  • TRI Air Handlers for Multi-Zone Placement
  • INVERTER DC TECHNOLOGY: 16 SEER
  • Intelligent Mechanical Defrosting
  • Washable Filters - Biologically Actv Enzyme
  • Low Startup Temps - MAXIMUM EFFICIENCY
  • Pre-charged with freon for 25\' [x3] of piping
  • Sleep Mode - 24 hour ON/OFF Timer - Memories
  • Enhanced Copper Coil - Wide Angle Air Spread
  • 3300 ft² coverage area: 900 + 1200 + 1200
  • Flexible, Quick Installation - Easy Operation

  • 18000 BTU Indoor Unit (air handler) specs: CLICK TO ENLARGE24000 BTU Indoor Unit (air handler) specs: CLICK TO ENLARGEOutdoor Unit (compressor) specs CLICK TO ENLARGE Install Kit Contents:
  • 25 Feet Flared Insulated Copper Tubing x 3
  • 25 Feet Pipe Insulation x 3

  • Drain Pipe (outdoor)
  • Mounting Brackets for Indoor Unit
  • Putty to seal piping / holes

  • Wire Harness Between Indoor & Outdoor x 3
  • Remote Control w/ Wall Brackets & Batteries x 3

  • ***Extend one or two (4) included 25 foot line sets to a total length of 50 feet. Just $124 per 25\' extension.***WHAT IS DC INVERTER?

    DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called \"DC inverter\" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result different running speeds of the compressor. YMGI Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter air conditioners bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically. Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly. Once the set temperature is reached, it slows down and adjust its capacity to counter the heat loss or heat gain of the building. By this way it will maintain a constant temperature.


    BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with Freon however, the lines still need to be vacuumed to evacuate the excess Nitrogen prior to the final coupling for operation.Although the installation may seem easy to some, certain tools and experience is necessary to complete installation of a mini split* See Installation Tip. A certified HVAC technician must conduct / complete the installation to be eligible for the warranty. (See warranty details below > )
    *5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship.Even though mini split setup is below the expertise requirements of central AC systems, these are not \"plug-n-play\" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns.Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and brand new exchange will be shipped out. Download Warranty Polices >

    These Mini Split units usually ship via SAIA Motor Freight (on truck) or some other freight service. These units ship out of Missouri and are in transit with 2 business days from payment receipt. Depending on where you are geographically located, transit time is usually between 3 and 6 business days. Please provide a contact phone# upon checkout where recipient of order can be reached. SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Only ships to the lower 48 Contiguous United States.


    Swap 18k Wall Mount for Ceiling Cassettes: (+) $135Swap 24k Wall Mount for Ceiling Cassettes: (+) $145Swap all 3 Wall Mounts for Ceiling Cassettes: (+) $385
    Swap 18k Wall Mount for Susp. Ceiling: (+) $248Swap 24k Wall Mount for Susp. Ceiling: (+) $298Swap all Wall Mounts for Susp. Ceiling Mounts: (+) $670
    *If alternate air handler types are preferred, request invoice with preferred options upon checkout or contact us.Customize your system to meet your requirements - see below table for available output options:
    Tri-Zone Setup12k + 18k + 24k18k + 18k + 18k12k + 24k + 24k9k + 24k + 24k18k + 18k + 24k18k + 24k + 24kQuad-Zone Setup9k + 12k + 12k + 24k9k + 9k + 18k + 24k9k + 12k + 18k + 24k9k + 12k + 18k + 18k9k + 18k + 18k + 18k12k + 12k + 18k + 24k12k + 12k + 12k + 24k12k + 12k + 18k + 24k9k + 9k + 24k + 24kQuint-Zone Setup9K +9K +9K +9K + 12K/18K/24K9K + 9K + 9K + 12K + 12K/18K/24K9K + 9K + 12K +12K + 12K/18K/24K9K + 12K + 12K + 12K + 12K/18K12K + 12K + 12K + 12K + 12K/18K09K + 09K + 12K + 12K + 18K09K + 09K + 12K + 18K + 18K09K + 12K + 12K + 18K + 18K12K +12K + 12K + 18K + 18KAir handlers are available in 9k, 12k, 18k and 24k outputs. Be advised, for arrangements where combined output of all heads exceeds rated capacity of condenser (60000 BTU\'s) - the total output will not exceed 60000\'s when all air handlers are running at full capacity simultaneously. However, overated zones will draw required capacity from other zones either running at lower settings or areas that have reached thermostat settings to obtain rated output. For example, with a 12k-12k-12k-12k-18k configuration, the total output will be along the lines of 11k-11k-11k-11k-16k when all zones are running on high/full settings at the same time. However, once a zone obtains set temperature and/or operates at a lower setting, the capacity will bleed off into zone that needs the extra push to obtain the 12k-12k-12k-12k-18k yield.
    *If alternate air handler types / capacities are preferred, request invoice with preferred options upon checkout or contact us.
    View the Mini Split FAQ >View the Mini Split Outline Diagram >Click to contact us >


    Buy Now

    Other Related Items:



    Related Items:

    5 Ton 14 SEER2 96% 120,000 BTU Horizontal Goodman Central AC Gas Split System picture

    5 Ton 14 SEER2 96% 120,000 BTU Horizontal Goodman Central AC Gas Split System

    $5295.30



    5 Ton 13.8-14 SEER2 Central Air & 120K BTU 96% Gas Furnace Split AC System Kit picture

    5 Ton 13.8-14 SEER2 Central Air & 120K BTU 96% Gas Furnace Split AC System Kit

    $4702.50



    Goodman 5 Ton 15.2 SEER2 AC & 80,000 80% Gas Furnace Split Horizontal System picture

    Goodman 5 Ton 15.2 SEER2 AC & 80,000 80% Gas Furnace Split Horizontal System

    $5529.00