Heat.net

Heat.net Store Home


Field Controls GVD-5 PL-CR Damper W/O Harness For Sale


Field Controls GVD-5  PL-CR Damper W/O Harness
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.

Buy Now

Field Controls GVD-5 PL-CR Damper W/O Harness :
$190.24

Description

Note: This item does not come with a harness.


The Field Vent Damper works automatically to allow natural draft during appliance operation while preventing residual appliance heat and conditioned air from escaping during off cycles. It also prevents the infiltration of cold air during down drafts.


Safety Features

Dual safety switches allow the burner to fire only when the damper is in the open position. This unit will not interfere with existing appliance safety controls, when properly installed.


Operational Features

Operates with all 24 VAC, 60hz intermittent ignition and standing pilot ignition systems.

Stainless steel construction provides superior corrosion resistance.

Damper operation: power opens in 15 seconds, power closes in 15 seconds. Power is off at damper motor when it is at rest.

Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems.

Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection.


Dimensions

Pipe Size: 5\"

Length: 6-1/16\"

Height: 9-7/8\"

Clearance: 15/16\"

Exposed Pipe: 4-13/16\"


How the GVD Works

The Field Vent Damper is installed in the vent pipe, after the draft hood, or barometric. During off cycles, it remains closed, preventing air flow through the vent. When there is a call for heat, the motor is energized, rotating the damper 90 degrees to an open position. Opening and closing takes approximately 15 seconds. When the damper is fully open, the burner is allowed to fire and flue gases pass freely through the vent. When the thermostat is satisfied, the burner stops, and the damper automatically closes. For service and trouble shooting, the damper can be locked in the open position.


Electrical Specifications

Minimum wiring requirements: 24 VAC - 18 gauge - 105 degrees C

Power requirements: 3 watts at 24 VAC, 60 Hz, when opening or closing

Specs

Diameter (Inches):

5\"


Width (Inches):

9-7/8\"


Length:

6-1/16\"


Application:

Air Quality


Voltage:

24v


Clearance:

15/16\"


Exposed Pipe:

4-13/16\"


Motor Timing:

15 Seconds Power Open


15 Seconds Power Closed


Shape:

Round


Buy Now

Other Related Items:



Related Items:

Field Controls PV6600 Power Ventor 6

Field Controls PV6600 Power Ventor 6"

$225.00



Field Controls 01950201 10'' M+MG2 Barometric Draft Control For Gas and Oil picture

Field Controls 01950201 10'' M+MG2 Barometric Draft Control For Gas and Oil

$280.00



NEW Field Controls 46273100 Adjustable Pressure Switch picture

NEW Field Controls 46273100 Adjustable Pressure Switch

$29.99