When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
365-Day Warranty!
Part Type: Fan Blower Control
Part Number: OEM Replacement Control
Upon application of power to the G terminal, the ICM277 recognizes a call for the blower and a 7 second delay on make period begins. After the 7 second ON delay, the control energizes the blower motor. Upon removal of power from the G terminal, the board will keep the blower on for an additional 65 seconds. At the end of the 65 second OFF delay, the blower will shut off.
For circulating fan in heat pump, A/C and forced air Voltage: 18-30 VAC
Contact Ratings:
– N.O.: 20 amps
– N.C.: 10 amps
Time Delays:
– Blower ON: 7 seconds fixed
– Blower OFF: 65 seconds fixedWEIGHT/DIMENSIONS:
Weight: 0.3
Height: 1.75
Width: 6
Length: 4.5
REPLACES:
Goodman: B1370735S, PCBFM131S
Listing and template services provided by inkFrog