Heat.net

Heat.net Store Home


NEW Resideo L4064B 2228 L4064 Fan & Limit 5\" Furnace Control For Sale


NEW Resideo L4064B 2228 L4064 Fan & Limit 5\
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.

Buy Now

NEW Resideo L4064B 2228 L4064 Fan & Limit 5\" Furnace Control:
$105.00

FRESH STOCK BRAND NEW CONTACT US WITH QUESTIONS NEW Resideo L4064B 2228 L4064 Fan & Limit 5\" Furnace Control
Product SpecificationsDescriptionFan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 5 in. insertionApplicationForced warm air heating systemsHigh Limit Temperature Range (F)100 F to 250 FHigh Limit Temperature Range (C)38 C to 121 CElement Insertion Length (in.)5 in.Element Insertion Length (mm)127 mmFan-on Range (F)65 F to 215 FFan-on Range (C)18 C to 102 CFan-off Range (F)50 F to 200 FFan-off Range (C)10 C to 93 CHigh Limit Stop (F)200 FFan-on Stop (F)125 FFan-off Stop (F)100 FSwitching ActionFan switch makes and high limit switch breaks on temperature rise.Electrical Rating Fan (AFL)14 A @ 120 VacElectrical Rating Fan (AFL)7 A @ 240 VacElectrical Rating Fan (ALR)84 A @ 120 VacElectrical Rating Fan (ALR)42 A @ 240 VacElectrical Rating Limit (AFL)4 A @ 240 VacElectrical Rating Limit (AFL)8 A @ 120 VacElectrical Rating Limit (ALR)24 A @ 240 VacElectrical Rating Limit (ALR)48 A @ 120 VacPilot Duty Ratings2 A @ 24 VacPilot Duty Ratings0.25 A @ 0.25 to 12 VdcOperating Temperature Range (F)-40 F to +190 FOperating Temperature Range (C)-40 C to +88 CDifferential Temperature (F)High limit 25 FDifferential Temperature (C)High limit 14 CMaximum Ambient Temperature (F)Switch: 190F; Sensing Element: 350 FMaximum Ambient Temperature (C)Switch: 88 C; Sensing Element: 177 CMountingRigid bracketDimensions (in.)4 9/32 in. high x 3 in. wide x 1 19/32 in. deep excluding elementDimensions (mm)109 mm high x 76 mm wide x 40 mm deep excluding elementApprovals, Underwriters Laboratories IncListed File MP466, Guide MBPRApprovals, Canadian Standards AssociationCertified: File No. LR1622CommentsTurns fan on and off according to plenum temperature. With helical bimetal sensing element. High limit stop set at 200F (93 C). With manual fan switch. Deluxe cover. Replaces L4064A,B,E.

RESIDEO Installation Manual and specifications:



Buy Now

Other Related Items:



Related Items:

NEW RESIDEO L8124A1007 TRIPLE AQUASTAT RELAY. S5 picture

NEW RESIDEO L8124A1007 TRIPLE AQUASTAT RELAY. S5

$229.99



NEW RESIDEO L8148E1299 AQUASTAT RELAY WITH MOLEX PLUG picture

NEW RESIDEO L8148E1299 AQUASTAT RELAY WITH MOLEX PLUG

$329.99



Brand New Resideo 943WG-WH Mini Magnetic Contact, White, 10pk picture

Brand New Resideo 943WG-WH Mini Magnetic Contact, White, 10pk

$59.99