Heat.net

Heat.net Store Home


S&A air cooled water chiller CW-5200AH 220V/50Hz for 2*100W laser or 8KW spindle For Sale


S&A air cooled water chiller CW-5200AH 220V/50Hz for 2*100W laser or 8KW spindle


This item has been shown 27 times.

Buy Now

S&A air cooled water chiller CW-5200AH 220V/50Hz for 2*100W laser or 8KW spindle:
$560

S&A CW-5200AH is refrigeration type circulating water chiller . It’s mainly used to cool down the temperature of equipment. The water temperature is able to be adjusted.

S&A industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature.

Features

1. 1400W cooling capacity; optional environmental refrigerant;

2. Compact size, long working life and simple operation;

3. ±0.3℃ precisely temperature control;

4. The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions;

5. Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;

6. Multiple power specifications; CE approval;RoHS approval;

7. Optional heater and water filter.

Specification

Model: CW-5200AH
Voltage: AC 1P 220V
Frequency: 50Hz
Current: 2.4~3.1A
Compressor power: 0.71HP
Refrigeration capacity: 1.49KW
Refrigerant: R-22 / R-134a / R-410a
Refrigerant charge: 360g
Precision: ±0.3℃
Reducer: Capillary
Protection: Overcurrent protection for compressor, flow alarm, over temperature alarm
Pump power: 0.05KW
Tank capacity: 6L
Inlet and outlet: External Φ10mm brass connector
Max. lift: 12M
Max. flow: 13L/min
N.W: 26 Kgs
G.W: 29 Kgs
Dimension: 58 X 29 X 47 cm (L X W X H)
Package dimension: 70 X 43 X 58 cm (L X W X H)

water chiller CW-5200AH is kept in stock for immediately delivery

Shipment

We will 7 Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded!
Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps).
2. Please make sure there is stable and normal voltage for the working chiller!
As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us.
3. Unmatched power frequency can cause the chiller damage!
Please choose model of 50Hz or 60Hz according to actual circumstance.
4. To protect the pump, it’s strictly forofferden to run the chiller without water in the storage water tank!
The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!
5. Please be sure that the air inlet and air outlet are in good ventilation!
There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.
6. The filter screen must be regularly cleaned!
It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.
7. Please pay attention to the effect of the condensate water!
With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.
8. The water temperature is at 20℃-30℃, it is the best for the refrigeration performance.Installation
It is very simple to install this industrial cooling machine.
S&A chiller has 2 temperature control modes as T503 intelligent temperature and T504 constant temperature control.
The new T503 intelligent temperature controller does not need to adjust the controlling parameters under normal circumstance. It will self-adjust controlling parameters according to room temperature for meeting equipment cooling requirements.The new T504 intelligent temperature controller is selected constant temperature control mode as factory setting with water temperature at 25℃. User can adjust it as needed.
If the chiller is T503 mode, please follow below steps: Firstly, please change intelligent temperature to constant temperature mode 1. Press and keep holding ▲and SET buttons, then wait for 5 seconds until "0" displayed
2. Press ▲ key to switch to "8" and release the key
3. Press "SET" key, and it displays "F0"
4. Press ▲ to turn to item "F3"
5. Press "SET" key and it displays "1"
6. Press▼ to adjust to "0"
7. Press "RST" key to save the modification
Now the chiller is working in constant temperature mode.Under constant temperature mode, you can manually adjust the temperature of S&A water chiller For exmaple, to set the water temperature at 35℃ 1. Press and keep holding ▲and SET buttons 2. Then for 5 seconds and it displays "0" 3. Press ▲ key to switch to "8" and release the key 4. Press "SET" key, and it displays "F0" 5. Press "SET" key again 6. Press▼ to adjust to "35" 7. Press "RST" key to save the modification

Buy Now

Other Related Items:



Diakin 5 Ton Gas/electric Package Unit,,14 Seer,, 208/230/3 Phase. picture
Diakin 5 Ton Gas/electric Package Unit,,14 Seer,, 208/230/3 Phase.


Diakin 15 Ton Straight Cool Package Unit 208/230//3 Phase picture
Diakin 15 Ton Straight Cool Package Unit 208/230//3 Phase


Diakin 6 Ton Gas/electric Package Unit 460/3 Phase. picture
Diakin 6 Ton Gas/electric Package Unit 460/3 Phase.


Diakin 10 Ton Gas/electric Package Unit 460/3 Phase. picture
Diakin 10 Ton Gas/electric Package Unit 460/3 Phase.


Diakin 3 Ton Straight Cool Package Unit ,,14 Seer,,460/3 Phase picture
Diakin 3 Ton Straight Cool Package Unit ,,14 Seer,,460/3 Phase


Diakin 20 Ton Gas/electric Package Unit 208/230//3 Phase picture
Diakin 20 Ton Gas/electric Package Unit 208/230//3 Phase


Diakin 15 Ton Gas/electric Package Unit 460/3 Phase picture
Diakin 15 Ton Gas/electric Package Unit 460/3 Phase


Diakin 20 Ton Straight Cool Package Unit 460/3 Phase picture
Diakin 20 Ton Straight Cool Package Unit 460/3 Phase