Heat.net

Heat.net Store Home


Vital Signs Patient Monitor 7 Parameter with wall bracket,Stand CMS8000 For Sale


Vital Signs Patient Monitor 7 Parameter with wall bracket,Stand CMS8000
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.

Buy Now

Vital Signs Patient Monitor 7 Parameter with wall bracket,Stand CMS8000:
$728.00




CONTEC FDA&CE ICU CCU Vital Signs Patient Monitor, 6 Parameters CMS8000 with cart Introduction
The monitor has abundantfunctions that can be used for clinical monitoring with adult, pediatric andneonate. Users may select different parameter configuration according todifferent requirements. The monitor, power supplied by 100-240V~,50/60Hz,adopts 12.1\'\' color TFT LCD displaying real-time date and waveform. It cansynchronously display eight-channel waveform and full monitoring parametersequipped with an optional 48mm thermal recorder. The monitor can be connected tothe central monitoring system via wire or wireless network to form a networkmonitoring system.
This device can monitor such parameters as ECG, RESP,NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurementmodule, display and recorder in one device to form a compact and portableequipment. Its replaceable internal battery brings lot of convenient for patientmoving.

Functions
Standardparameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG Heartrate(HR)
ECG waveform
Arrhythmia and ST-segmentanalysis
2)RESP Respiration rate(RR)
Respirationwaveform
3)SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH)waveform
Pulse rate(PR)
Bar graph
4)NIBP Systolicpressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP T1, T2,TD
6)IBP(optional) CH1:SYS,DIA,MAP
CH2:SYS,DIA,MAP
IBPwaveform
7)CO2(optional) EtCO2
InsCO2:Inspired Minimum CO2
AwRR:AirWay Respiration
It has abundant functions, such as audible and visual alarm,trend data storage and output, NIBP measurement, alarm event marking and drugconcentration calculation, etc.

Features
1)12.1\'\' TFT color LCD,multi-language interface(Simplified Chinese, Traditional Chinese, English,French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian,Kazakh, Polish, Czech).
2)Fanless design, quiet, energy-saving and clean,which reduces the possibility of cross-infection.
3)All-round monitor foradult, pediatric and neonate.
4)With standard interface, oxygen graph, trendgraph, big character interface and view bed, convenient to observe.
5)Finishall operations by keys and knobs.
6)Maximum 8-channel waveform synchronousdisplay.
7)Display 7-lead ECG waveform on one screen, cascade ECG waveformdisplay
8)Adopt digital SpO2 technology, anti-motion and anti-ambient lightinterference, and measurement can be performed under the circumstance of weakfilling.
9)Heart rate variability (HRV) analysis function
10)NIBPmeasurement mode: Manual/AUTO/STAT, storage for 4800-group NIBPdata.
11)Review for 71 alarm events of all parameters and 60 arrhythmia alarmevents.
12)Drug concentration calculation and titration tablefunctions.
13)One-touch printing of trend graph
14)Connect to CentralMonitoring System by 3G, Wi-Fi or wired mode.
15)AC/DC, built-in rechargeablelithium battery achieve uninterrupted monitoring.
16)Anti-high frequencysurgical unit, defibrillation-proof (special leads arenecessary).

Performance
▲ECG
Lead mode: 3-lead or5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead,dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range: 15~350 bpm
Accuracy: ±1 % or ±1 bpm,whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1bpm
ST-segment monitoring:
Measurement and alarm range: -2.0 mV ~ +2.0mV
Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC,COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,
PVC, TACHY, BRADY, MISSEDBEATS, PNP, PNC
Pacemaker: yes
▲RESP
Method: R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range: 0~150 rpm
Resolution:1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm:10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
▲NIBP
Method:Oscillometry
Mode: Manual/AUTO/STAT
Measurement interval in AUTO minutes
Measurement period in STATmode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximal meandeviation: ±5 mmHg
Maximal standard deviation: 8 mmHg
Over-pressureprotection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3mmHg
Neonatal mode: 147±3 mmHg
▲SpO2
Measurement and alarm range: 0 ~100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%:unspecified
▲PR
Measurement and alarm range: 30 ~ 250 bpm
Measurementaccuracy: ±2 bpm or ±2%, whichever is greater
▲TEMP
Channel:dual-channel
Measurement and alarm range: 0 ~ 50℃
Resolution: 0.1℃
Accuracy: ±0.1 ℃
▲EtCO2
Method: Sidestream or Mainstream
Measuring Range: 0~150mmHg
Resolution:
0~69 mmHg, 0.1 mmHg
70~150mmHg, 0.25 mmHg
Accuracy:
0~40 mm Hg ±2 mm Hg
41~70 mm Hg ±5%
71~100mm Hg ±8%
101~150 mm Hg ±10%
AwRR Range: 2~150 rpm
AwRR Accuracy:±1BPM
Apnea Alarm: Yes
▲IBP(Optional function)
Channel: dual-channel
Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range: -10~300mmHg
Resolution 1 mmHg
Accuracy: ±2% or 1mmHg, whichever isgreater
▲Power supply: 100-240V~, 50/60Hz
▲Safety classification: Class I,type CF defibrillation-proof applied part

Accessories
1)Adult fingertip SpO2 probe(5-pin)
2)Adult NIBP cuff
3)NIBP extension tube
4)ECG leadcable
5)ECG electrode
6)Temperature probe
7)Power cord
8)UserManual9)Cart

Physicalcharacteristic
Dimension: 314 mm(L) × 145 mm(W) × 264mm(H)
Weight: 3.9 Kg
Buy safe products
The following FDA Disclaimer is required for all listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved
International Buyer--Please note:
Import duties,Taxes are not included in the item price.These charges are buyers\' responsibility

We are the manufacturer of medical equipment for 17 years, the following are our main products:
ECG / ECG holter EEG / EEG Holter B-ultrasound
Patient Monitor Fetal doppler Fetal Monitor
Spo2 Monitor Stethoscope Medical Image....
Agent in the world!
We are look for partners in the world now!
Do you want to become our agent in you conutry?
Join US!
Skype:xuebox3
contec.med.mary at hotmail.com

Only English User Manual,Please contact us if you need other language version.thank you
Buy Now

Other Related Items:



Related Items:

Vital Signs Patient Monitor ECG NIBP RESP TEMP SPO2 PR,choose stand FDA picture

Vital Signs Patient Monitor ECG NIBP RESP TEMP SPO2 PR,choose stand FDA

$299.00



Vital Signs Monitor NIBP Patient Monitor SPO2,NIBP,Pulse Rate,24hrs Ambulatory picture

Vital Signs Monitor NIBP Patient Monitor SPO2,NIBP,Pulse Rate,24hrs Ambulatory

$179.00



Portable 10” Vital Signs Monitor ECG NIBP RESP TEMP SPO2 PR - Accurate Health CE picture

Portable 10” Vital Signs Monitor ECG NIBP RESP TEMP SPO2 PR - Accurate Health CE

$438.93