Technical Specifications Electrical With display No Voltage type for actuating AC/DC Rated operating voltage Ue 200 V Rated control supply voltage at AC 50 Hz 100 V Rated control supply voltage at AC 60 Hz 100 V Overload current 5.3 A Controller type SMC-3 DV/DT protection 1000V/µs for power circuit Repetitive peak voltage 1400V per UL/CSA/NEMA for power circuit Operating frequency 50/60 Hz per UL/CSA/NEMA for power circuit Line connected motor power, max 7.5 kW @ 380/400/415V AC, 50 Hz, 3-phase Delta connected motor power, max 5...15 Hp @ 460V AC, 60 Hz, 3-phase Overvoltage category III per IEC for side mount auxiliary contacts Rated impulse voltage 6 kV for power circuit Dielectric withstand 2500V AC per IEC for power circuit Line connected motor current 5.3...16 A @ 380/400/415/460V AC, 3-phase Delta connected motor current 9.1...27.6 A @ 380/400/415/460V AC, 3-phase Insulation voltage Rated 600V AC per UL/CSA/NEMA for power circuit Rated operational voltage 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts Rated control power during start with fan 215 mA @ 120V AC/180 mA @ 240V AC, 800 mA @ 24V DC/660 mA @ 24V AC Input OFF-state current <10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit Short-circuit protection device list Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L Number of contacts TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts High capacity available fault current, max 69 kA @ 600V, maximum current 60 A time delay Class J or Class L fuse for inside delta connected motors Type of current TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts Conventional thermal current (Ith) TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts Type of control circuit TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts Type of contacts TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts Utilization category TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts Rated operational current, max TB-97, -98 (OVLD/Fault): 0.6 A @ 120V AC and 0.3 A @ 240V AC for auxiliary contacts Standard controller feature Soft stop Standard available fault current, max 5 kA @ maximum standard fuse 70 A for delta device operational current rating Integrated motor overload protection Yes Short circuit protection device performance (SCPD) type Type 1 Selectable overload trip class Trip Class 10, 15, or 20 Selectable start times 2, 5, 10, 15, 20, 25, or 30 s Input OFF-state voltage (IN1, IN2), max 40V AC, 17V DC/12V AC for control circuit Selectable current limit 150%, 250%, 350%, and 450% of full load current Input ON-state voltage, during start (IN1, IN2) 85V AC, 19.2V DC/19.2V AC minimum for control circuit Rated control power during start without fan 205 mA @ 120V AC/145 mA @ 240V AC, 705 mA @ 24V DC/580 mA @ 24V AC Input ON-state current (IN1, IN2) 9.8 mA @ 120V AC/19.6 mA @ 240V AC for control circuit, 7.3 mA @ 24V AC/DC for control circuit Mechanical Degree of protection (IP) IP2X Weight 0.86 kg Shock Operational: 15 G Width 44.8 mm (1.76 inch) Depth 110 mm (4.33 inch) Height 139.7 mm (5.5 inch) Cable size 2.5...25 mm² (14...4 AWG) for line power terminals Vibration Operational: 1.0 G peak, 0.15 mm (0.006 inch) displacement Make TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts Break TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts Tightening torque 2.3...3.4 Nm (30 lb.inch) for line power terminals, 4.0 Nm (35 lb.inch) if 25 mm² (4 AWG) wire in top terminal for line power terminal Internal bypass Yes Function Single direction Selectable kick start - 450% FLA 0, 0.5, 1.0, or 1.5 s Selectable initial torque 15%, 25%, 35%, and 65% of locked rotor torque Selectable soft stop Off, 100%, 200%, or 300% of the start time setting when wired Environmental Steady state heat dissipation 14 W Storage and transportation temperature -25 °C Rated surrounding temperature range without derating -5 °C Humidity 5...95% noncondensing Operating temperature Open: -5 to 50 °C (23 to 122 °F) EMC emission levels Radiated emission: Class A per IEC EMC immunity levels Surge transient: per EN/IEC 60947-4-2 per IEC Altitude 2000 m Pollution degree 2 Construction Mounting hole size 4.6 mm Number of poles Equipment is designed for 3-phase only for power circuit Enclosure Open type